OPTIFLUX 6300

Electromagnetic flowmeter for advanced hygienic applications

  • High accuracy (±0.2%), for exact dosing or filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6″ (3A, EHEDG certified)
  • Many hygienic fittings
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

The OPTIFLUX 6300 is an electromagnetic flowmeter (EMF) for advanced hygienic applications in the food sector. The high-end flowmeter is particularly suitable for blending, dosing or filling applications where a high accuracy (±0.2% of measured value) is priority and extensive diagnostics are required. In addition, it can even be used for low conductivity liquids of 1 μS/cm (e.g. glucose, fruit concentrates). The 3A and EHEDG certified flowmeter comes with industry specific installation lengths. It has no crevices, gaps or blind spots and is specifically designed to stay clean and sterile. This way, it complies with the most stringent demands in the food and beverage industry.

Product positioning

For advanced hygienic applications

Measurement principle

Electromagnetic

Measured media

Liquids

Operating conditions

Process pressure

max. 40 barg/580 psig

Process temperature

-40…+140°C/-40…+284°F

Materials

Liner Perfluoroalkoxy alkane (PFA)

Process connections

Hygienic connections Clamp (DIN 32676): DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150;

Clamp (ISO 2852): 12, 17.2, 25, 38, 51, 63.5, 76.1, 101.6, 114.3, 139.7;

Tri-Clamp: ½”, ¾”, 1″, 1½”, 2″, 2½”, 3″, 4″, 5″, 6″;

Threaded ferrule (DIN 11851): DN10, DN15, DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150;

Flange with groove (DIN 11864-2): DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150;

Threaded ferrule (SMS 1146): 25 mm, 38 mm, 51 mm, 63.5 mm, 76 mm, 101.6 mm;

Aseptic weld end fitting (DIN 11850 / EN 10357): DN2.5, DN4, DN6, DN10, DN15, DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150;

Aseptic weld end fitting (ISO 2037): 12, 17.2, 25, 38, 51, 63.5, 76.1, 101.6, 114.3, 139.7

Approvals/Standards

Certificates/Approvals Custody transfer (CT) MI-005, OIML R117

Certificates/Approvals Ex ATEX, IECEx, NEPSI, EAC Ex, INMETRO, FM, CSA, KCs, PESO, IA

Certificates/Approvals Hygienic FDA, 3A, EHEDG, EC 1935/2004, EC2023/2006

Communication

Analogue outputs 4…20 mA

Discrete outputs Limit switches, Pulse, Frequency, Status

Digital outputs FOUNDATION™ Fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, PROFINET

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Bi-directional flow measurement over a wide dynamic range (turn down ratio: 1000:1)
  • Designed for conductive liquids 1 μS/cm (water: 20 μS/cm)
  • Suitable for solid content up to 70%, e.g. yogurt with fruit pieces, soups with vegetable pieces etc.
  • Standard measurement accuracy: ±0.2% or ±1mm/s of measured value (MV)
  • Extensive sensor and process diagnostics
  • PFA liner reinforced with embedded stainless steel grid for vacuum resistance
  • Certified to 3A, EHEDG; complies with FDA and EC1935/2004 regulations
  • Unique L-shaped gasket prevents expansion of gasket for increased life time
  • Compact version or remote version with wall-mount, field or rack-mount housing
  • Also available with stainless steel compact or field housing
  • Available with industry specific installation lengths and various hygienic process connections
  • Diagnostics incl. conductivity, electrode error, ambient and process temperature etc.
  • Full bore design: No moving parts, no wear, no pressure loss
  • On-site verification of flowmeter with OPTICHECK service tool