The robust Promass E has a long-standing reputation as a reliable solution accurately measuring liquids and gases in a wide range of standard applications in the chemical industry. With genuine loop-powered technology, Proline E 200 enables cost-effective and seamless integration into existing infrastructures. The flowmeter offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.
Measuring principle operates independently of physical fluid properties such as viscosity or density. Accurate measurement of liquids and gases for a wide range of standard applications. Genuine loop-powered flowmeter for minimized cost of ownership. Accurate measurement of liquids and gases for a wide range of standard applications.
DN 8 to 50 (⅜ to 2″)
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Mass flow (liquid): ±0.25 % (standard)
Volume flow (liquid): ±0.25 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³
0 to 70 000 kg/h (0 to 2570 lb/min)
PN 100, Class 600, 63K
–40 to +150 °C (–40 to +302 °F)
–40 to +60 °C (–40 to +140 °F)
1.4301 (304), corrosion resistant
AlSi10Mg, coated
IP66/67, type 4X enclosure
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
None
HART, PROFIBUS PA, FOUNDATION Fieldbus
DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
ATEX, IECEx, cCSAus, JPN, UK Ex
CE, C-Tick
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
PED, CRN
3.1 material
3-A, EHEDG, cGMP
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).