Promass S is at the forefront in hygienic design – Endress+Hauser’s industry-optimized measurement solution meets all the hygienic requirements for installation in the Food and Beverage industry. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications where space is a premium, Promass S 100 will be the preferred choice for system integrators, skid builders and equipment manufacturer.
Measuring principle operates independently of physical fluid properties such as viscosity or density. Dedicated for applications requiring optimal cleanability under hygienic conditions. Easy-to-clean flowmeter with self-drainable single-tube system and an ultra-compact transmitter. Dedicated to applications requiring optimal cleanability under hygienic conditions.
DN 8 to 50 (⅜ to 2″)
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
0 to 70 000 kg/h (0 to 2570 lb/min)
PN 40, Class 150, 20K
–50 to +150 °C (–58 to +302 °F)
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
1.4301 (304), corrosion resistant
Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)
Standard: IP66/67, type 4X enclosure
Option: IP69
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
None
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
DC 20 to 30 V
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
CE, C-Tick, EAC marking
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
PED, CRN
3.1 material
3‐A, EHEDG, cGMP
Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest