The Prosonic FMU41 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m. Two-wire or four wire instrument for continuous non-contact level and flow measurement. Process connection: Thread. Temperature: -40 to +80°C (-40 to +176°F). Pressure: +0.7 to +3bar (+10 to +44psi). Maximum measuring distance: Liquids 8m (26ft), Solids 3.5m (11ft). Blocking distance: Liquids and Solids 0.35m (1.15ft). International explosion protection certificates.
Ultrasonic
Compact ultrasonic transmitter
2-wire HART
+/- 2 mm or +/- 0,2 % of set measuring range
-40 °C … 80 °C
(-40 °F … 176 °F)
-40 °C … 80 °C
(-40 °F … 176 °F)
0.7 bar … 3 bar abs
(10 psi … 44 psi)
PVDF
G / NPT 2″
0.35 m (1.15 ft)
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft)
4…20 mA HART
ATEX, FM, CSA, IEC, INMETRO, NEPSI
For higher resistance:
FMU42/FDU9x
FMU42/FDU91
FMU90 + FDU9x
FMU90 + FDU9x