SmartLine Non Contact Radar Level Transmitters

SmartLine Level Transmitter uses Non Contact radar (NCR) 80 GHz FMCW technology and can measure the level of a wide range of liquid and Solid products on a large variety of installations within the stated pressure and temperature range.

The SmartLine® SLN700 Series Non Contact Radar Level Transmitters deliver value across the entire plant lifecycle by helping users:

  • Reduce engineering effort, project costs and startup time
  • Avoid application errors and unplanned downtime
  • Increase security against unauthorized access
  • Reduce spare parts inventory
  • Minimize maintenance through the non contact measuring principle

The SmartLine® Non Contact Radar Level Transmitter employs the latest 80 GHz technology, modular design, an advance display, and intelligent false echo detection algorithms to deliver highly accurate level measurements and best-in-class performance.

The non contact design can measure a wide range of applications in liquid and solid level measurements with the stated pressure and temperature range. It can be utilized on process tanks, storage tanks, mobile containers, and bulk solid silos. This state of the art the level transmitter is capable of measuring media with a dielectric constant of 1.4 or greater. The integrated and encapsulated antenna designs allow for deployment in even narrow tank installations while still providing level measurement for liquids up to 30m and solids up to 120m.

The SLN700’s Principle of Operation utilizes an 80 GHz Frequency Modulated Continuous Wave or FMCW to make a highly accurate level measurement.

  • First, a radar wave is continuously emitted through a specific frequency range.
  • The radar wave travels through air and is reflected back when a surface of different di-electric than air is encountered.
  • When the reflected wave is received back at the point of launch, a time delay is linked to the wave propagation.
  • The difference in the frequency of the emitted wave and received wave are captured and quickly processed using Fast Fourier Transform or FFT calculations and a highly accurate distance and level measurement are achieved.

The SLN700 Series SmartLine® Non Contact Radar Level Transmitter offers:

Modular design:

Reducing inventory and enhancing flexibility

Rich, advanced display and local configuration capabilities:

In addition to configuring with any handheld device using the new DTMs, users can configure the transmitters through buttons on display

Integration with all control systems:

This includes seamless integration with Experion® PKS that provides extended diagnostics, maintenance status display and transmitter messaging.

Measurement Technology

Uses 80 GHz FMCW (Frequency-Modulated Continuous Wave) radar.

Narrow beam, small “blind zone” — good for tight / narrow tanks.

False-echo suppression capability to ignore unwanted reflections.

Because it’s non-contact, the sensor is less affected by media build-up, foaming, or variations.

Performance

Very good accuracy: ± 2 mm (per Honeywell spec) for many models.

High resolution for detailed level measurement.

Measuring range: up to 30 m for liquids, 120 m for solids (depending on configuration).

Process Conditions / Robustness

Can operate over a wide temperature range: –40 °C to +200 °C in many versions.

Pressure range: can handle down to 1 bar (vacuum) up to +25 bar for certain models.

Immune to many process interferences: temperature, pressure, dust, and most obstacles don’t significantly affect performance.

Dielectric constant: works for media with a dielectric constant ~1.4.

Design / Modularity

Modular design: electronic module can be replaced without replacing the entire unit → reduces spare-part inventory.

Small, encapsulated antenna → easy to install even in constrained or narrow nozzles.

Advanced local user interface: graphic LCD display + push-button configuration for zero, span, etc.

360° housing rotation: you can mount / orient the transmitter for optimal display visibility.

Output / Communication

Standard analog output: 4–20 mA.

Digital protocols supported: HART and FOUNDATION™ Fieldbus.

Operating voltage: 12 to 30 V DC.

Diagnostics / Safety

Built-in diagnostics: health monitoring, false-echo detection, and other check functions.

Modular electronics: can swap electronics in field with no loss of calibration or performance.

Compatible with Honeywell Experion PKS for deep integration: supports extended diagnostic messaging and maintenance-status indications.

Features

  • Ideal for liquid storage tanks, even under difficult conditions (foam, agitation, dust).
  • Solid bulk measurement: useful in silos / hoppers because of the long measuring range.
  • Open-channel / flow measurement: can be used for level-based flow calculations when channel geometry is known.
  • Low-maintenance applications: non-contact means less fouling, less drift, and fewer maintenance interventions.
  • Because of modular design, only specific parts may need replacing (not the whole transmitter).
  • Helps reduce engineering risk / inventory cost because of common SmartLine modules.
  • Strong long-term product support as part of the SmartLine family.