SmartLine Guided Wave Radar Level Transmitters

SmartLine Level transmitters use guided wave radar (GWR) technology and can measure the level of a wide range of liquid products on a large variety of installations within the stated pressure and temperature range. With best-in-class performance, modular construction, an advanced display and the best integration features, SmartLine® Level Transmitters deliver total value across the entire plant lifecycle by helping users:

  • Reduce engineering effort, project costs and startup time
  • Avoid unplanned downtime and application errors
  • Increase security against unauthorized access
  • Reduce spare parts inventory
  • Shorten time to repair. ​​​​​

Honeywell offers the SmartLine Level Application and Validation Tool that helps users determine the optimal measurement solution for their application.


SmartLine Level Transmitter uses guided wave radar (GWR) technology and can measure the level of a wide range of liquid products on a large variety of installations within the stated pressure and temperature range. It can be deployed at blending tanks, distillation columns, process tanks, separators, solid silos (inventory) and storage tanks. It does not require calibration or commissioning upon installation, and can measure liquid interface with or without an air gap. Additionally, the level meter can measure the level and interface simultaneously, and is capable of measuring media with a dielectric constant of 1.4 or greater. A variety of rigid and flexible probes allow measurement in silos and tanks up to 50 m (164 ft) high. SmartLine Level Transmitter offers:

  • A new validation tool to avoid costly errors upfront by validating the level transmitter against the process tank
  • A joint, online collaborative engineering session with Honeywell level experts right at users’ desktop
  • Modular design: Some modules are shared with SmartLine pressure and temperature transmitters, further reducing inventory and enhancing flexibility
  • Rich, advanced display and local configuration capabilities: In addition to configuring with any handheld device using the new DTMs, users can configure the transmitters through externally accessible buttons, even in an intrinsically safe environment.
  • Integration with all control systems: This includes seamless integration with Experion® PKS that provides extended diagnostics, maintenance status display and transmitter messaging.

SmartLine Level Transmitters are used in applications where technologies such as capacitance, hydrostatic level or ultrasonic level measurements may have been used earlier. Immune to changes in conductivity, density, pressure and temperature, the level meters offer better reproducibility and accuracy than these other technologies. Since the signal travels up and down the probe, it is also unaffected by the angle of repose of a granular material.

Measurement Technology

Uses guidedwave radar (GWR): microwave pulses travel down a probe (rigid or flexible), reflect at the liquid surface, and return.

Can measure level and interface (liquid / interface measurement) simultaneously.

Works with media dielectric constant ~1.4.

Performance / Accuracy

Accuracy: ± 3 mm or ± 0.03% of measured distance (whichever is greater).

Repeatability: ± 1 mm.

Measuring range: up to 50 m (164 ft), depending on probe.

Process Conditions

Process temperature range: –60 °C to +450 °C.

Process pressure range: –1 bar to 400 bar.

Wetted materials: options like 316L stainless steel and Hastelloy C-276.

Signal Output & Communication

420 mA (two-wire) output.

Digital communication: HART v7 and FOUNDATION™ Fieldbus.

External zero, span, and configuration via push-buttons.

Safety & Reliability

Integral dual-seal design for safety and compliance (ANSI/NFPA 70202, ISA 12.27.01).

On-board diagnostics: health monitoring built in.

Functional safety capable: SIL 2 / SIL 3 options.

Design / Integration

Modular construction: modules can be shared with other SmartLine instruments (pressure, temperature) — lowers spareparts cost.

Advanced local display: has a rich display that supports multiple screens (e.g., process variable, bar graph, trends) and configuration buttons.

Polarityinsensitive terminals → reduces wiring errors.

SmartLine Application & Validation Tool: helps users validate the correct transmitter for their tank / process installation.

Integration with Honeywell Experion PKS: extended diagnostics, transmitter messaging, maintenancestatus display.

Industrial Safety Services

Robustness / Lifecycle

Loop-powered (2wire) design simplifies installation.

Tamper notification to enhance security.

Temperature compensation for stable readings over a wide temperature range.

Features

  • Process tanks, blending tanks, separators, distillation columns.
  • Measuring liquid interfaces, even with air gaps.
  • High-temperature or high-pressure applications, thanks to wide process range.
  • Applications where other level technologies struggle: e.g., hydrostatic, capacitance, or ultrasonic — GWR is less sensitive to conductivity, density, temperature.