Proline Prowirl D 200 vortex flowmeter

The Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. With genuine loop-powered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

Cost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates. Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic). For all basic applications and for 1-to-1 replacement of orifice plates.

Device properties

  • Face-to-face length of 65 mm (2.56 in)
  • No flanges
  • Low weight
  • Display module with data transfer function
  • Robust dual-compartment housing
  • Plant safety: worldwide approvals (SIL, Haz. area)

Benefits

  • Integrated temperature measurement for mass/energy flow of saturated steam
  • Easy alignment of the sensor – included centering rings
  • High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer
  • Long-term stability – robust drift-free capacitive sensor
  • Convenient device wiring – separate connection compartment
  • Safe operation – no need to open the device due to display with touch control, background lighting
  • Integrated verification – Heartbeat Technology

Nominal diameter range

DN 15 to 150 (½ to 6″)

Wetted materials

Measuring tube: 1.4408 (CF3M)

DSC sensor: 1.4435 (316/316L)

Measured variables

Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error

Volume flow (liquid): ±0.75 %

Volume flow (steam, gas): ±1.00 %

Mass flow (liquid): ±0.85%

Mass flow (steam, gas): ±1.7 %

Measuring range

Liquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min)

depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)

Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min)

depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Standard: –40 to +260 °C (–40 to +500 °F)

High/low temperature (option): –200 to +400 °C (–328 to +752 °F)

High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

Ambient temperature range

Compact version (standard): –40 to +80 °C (–40 to +176 °F)

Compact version (option): –50 to +80 °C (–58 to +176 °F)

Remote version (standard): –40 to +85 °C (–40 to +185 °F)

Remote version (option): –50 to +85 °C (–58 to +185 °F)

Sensor housing material

Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material

AlSi10Mg, coated; 1.4404 (316L)

Degree of protection

Compact version: IP66/67, type 4X enclosure

Sensor remote version: IP66/67, type 4X enclosure

Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

4‐line backlit display with touch control (operation from outside)

Configuration via local display and operating tools possible

Remote display available

Outputs

4‐20 mA HART (passive)

4‐20 mA (passive)

Pulse/frequency/switch output (passive)

Inputs

Current input 4‐20 mA (passive)

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)

DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)

DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)

DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

Product safety

CE, C-TICK, EAC

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine approvals and certificates

ABS, LR, BV, DNV

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material

NACE MR0175/MR0103, PMI (on request)

Sensor features

Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.

Transmitter features

Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).