CoriolisMaster FCH100 series

CoriolisMaster FCH100 series of compact hygienic system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus communication and 2 digital outputs. The FCH100 series offers on top EHEDG certified cleanability with polished wetted materials.


With no up or downstream piping requirements the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before.

The FCH100 series delivers:

  • EHEDG, hygienic certification
  • Superior accuracy and speed for filling applications
  • Full parameter access with up to 115 kBaud
  • Aluminum housing or all stainless steel solution
  • DTM based diagnostic and operability functions

The sensor delivers:

  • Multivariable measurement of mass flow, density and temperature in one device
  • Low pressure drop save 25 % on pump energy costs compared to other brands
  • Wide measurement span in a single meter

FCH150 adds:

  • DensiMass: High accuracy concentration measurement, watercut and net-oil computing as well as net-mass and net-volume measurement
  • FillMass: Filling application software with integrated precounter, overand underfill correction and contact output for valve control

Nominal sizes / measuring ranges

  • DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
  • DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
  • DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)

Ex approvals

  • ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2

Wetted materials

  • 1.4404 / 1.4435 (316L)

Accuracy for liquids FCH130

  • Mass and volume: 0.4 % o. r. / 0.25 % o. r.
  • Density: 10 g/l

Accuracy for liquids FCH150

  • Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
  • Density: 2 g/l or 1 g/l

Measuring medium temperature FCH130

  • -50 to 160 °C (-58 to 320 °F)

Measuring medium temperature FCH150

  • -50 to 205 °C (-58 to 400 °F)

Outputs

  • 2 digital out (pulse, frequency, contact)
  • Modbus

Power supply

  • 11 to 30 V DC

Hygienic design: EHEDG certified cleanability with polished wetted materials. Compact installation: No requirement for long straight pipe runs upstream or downstream; enables installation in tight spaces. Multivariable measurement: The device measures mass flow, density and temperature in a single unit. Low pressure drop: Saves up to ~25 % pump energy costs compared with other brands. Highspeed communication: RS485 Modbus communication up to ~115 kBaud; 2 digital outputs (pulse/frequency/contact) standard. Housing options: Available in aluminium housing or full stainless steel solution.