STT650 Smart Temperature Transmitter

STT650 DIN rail mounted temperature transmitters offer high measurement accuracy, stability and reliability over a wide range of process and ambient temperatures.When you need high-accuracy temperature measurement in a panel / control cabinet. For applications with tight space constraints, since it’s DIN-rail mountable. In systems where noise / electrical interference is a concern (because of its galvanic isolation and surge robustness).

Their compact designs, along with dual channel options, help accommodate multiple temperature measurements on a panel, thus lowering both costs and inventory. Designed to deliver very high performance, the SmartLine STT650 easily meets the most demanding needs for temperature measurement, allowing it to replace virtually any transmitter available today. If you want cost-efficient redundancy: the dual-channel model helps reduce component count. When using common industrial protocols: HART, Fieldbus, or Profibus.

Performance & Accuracy

Accuracy: ± 0.1 °C (for RTD input).

Update / response time: up to 135 ms.

Measurement stability: 0.12% of span over 2 years.

Reliable Measurement / Signal Integrity

Built-in galvanic isolation: 1,500 VAC.

High noise immunity: tested for 2 kV surge / 2.5 kV burst.

Sensor error detection: supports NAMUR NE43 error response.

Input Flexibility

Supports RTD (Pt100, Ni100), thermocouples, ohm, and mV inputs (depending on variant).

Offers single or dual channel models, which is useful for handling multiple measurements from the same rail.

Output / Communication Options

4–20 mA analog output standard.

Protocol support: HART 7, FOUNDATION Fieldbus, PROFIBUS PA (depends on model).

Programmable via PC using the STT17C configuration tool.

Operating Conditions & Power

Ambient temperature range: –40 °C to +85 °C.

Supply voltage: 8–30 VDC for intrinsically safe versions, up to 35 VDC for non-IS version.

Programmable damping: 0.33 to 60 seconds.

Diagnostics & Maintenance

Built-in sensor diagnostics for detecting sensor faults.

Compact DIN-rail design: saves over 50% panel space, reducing cost and footprint.

Easy configuration and commissioning: less complicated setup.

Safety & Certification

Assessed by EXIDA for use in SIL (Safety Integrity Level) applications.

EMC/EMI & surge testing passed (per spec sheet).

Mechanical / Physical

DIN-rail mountable (per EN standard).

Compact form factor for panel use

Features

  • High accuracy – 0.1°C for RTD
  • Faster response, up to 135 ms update
  • Stable measurement, 0.12% of span for two years
  • Иuilt-in 1500 VAC galvanic isolation
  • Superior noise performance – tested for 2 KV surge/2.5 kv burst noise
  • Sensor diagnostics
  • Simple and easier configuration
  • Compact design, saving over 50% panel space