EJXC50A, EJAC50E Gauge Pressure Direct Mounted Seal

Direct Mounted Diaphragm Seal System consists of gauge pressure transmitter with single direct mount diaphragm seal. Suitable for various kinds of pressure measurement. Explosion-proof and intrinsically safe versions available. Stainless steel wetted parts and multiple seal materials for compatibility. Compact design simplifies installation in tight spaces.

High accuracy and stability thanks to Yokogawa’s digital sensor technology. Direct-mounted diaphragm seal allows measurement of viscous, corrosive, or high-temperature media. Excellent temperature performance – minimal drift in changing process temperatures. Wide pressure ranges available to fit various industrial applications. Robust construction for harsh environments, including chemical, oil & gas, and food industries. HART / FOUNDATION Fieldbus / Profibus communication options. Advanced self-diagnostics for predictive maintenance. 

Type

Direct-mount flanged diaphragm seal system

Measurement/Span & Range (EJXC50A)

Span A: 8 … 200 kPa, Range: –100 … +200 kPa

Span B: 0.04 … 2 MPa, Range: –0.1 … +2 MPa

Span C (Flush): 0.2 … 10 MPa, Range: –0.1 … +10 MPa

Extended type: 0.2 … 7 MPa, Range: –0.1 … +7 MPa

Measurement/Span & Range (EJAC50E) 

Span A: 10 … 200 kPa, Range: –100 … +200 kPa

Span B: 0.1 … 2 MPa, Range: –0.1 … +2 MPa

Span C (Flush): 0.5 … 10 MPa, Range: –0.1 … +10 MPa

Extended type: 0.5 … 7 MPa, Range: –0.1 … +7 MPa

Ehuade Automation

Process Connection (Seal)

Flush flanged seal: 1½″ (40 mm), 2″ (50 mm), 3″ (80 mm)

Extended flanged seal: 3″ (80 mm), 4″ (100 mm)

Response Time

120 ms

Filling Fluid

Silicone oil (various types depending on temperature)

Process Temperature (Fluid) Depends on fill fluid

“Generaluse” silicone oil (code A): –10 °C … +315 °C

Silicone oil “low temp” (code F): –70 °C … +100 °C

Ambient (Electronics) Temperature

–10 °C … +85 °C (for general-use version)

Working Pressure / Overpressure Up to the flange rating pressure (depends on seal size / rating)

Specific Gravity of Filling Fluid ~1.07 (general-use oil), ~0.94 (high-temp version), ~0.88 (low-temp)

Applicable Safety / Certification

Supports LPS (Local Parameter Setting), is part of Yokogawa’s OpreX field instruments line.

Features

  • High Accuracy
  • Safety as Standard
  • 120 msec Response Time
  • LPS (Local Parameter Setting)
  • Signal Characterizer for the 4 to 20 mA output