Ultrasonic measurement Time-of-Flight Prosonic FMU41

The Prosonic FMU41 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate


Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m. Two-wire or four wire instrument for continuous non-contact level and flow measurement. Process connection: Thread. Temperature: -40 to +80°C (-40 to +176°F). Pressure: +0.7 to +3bar (+10 to +44psi). Maximum measuring distance: Liquids 8m (26ft), Solids 3.5m (11ft). Blocking distance: Liquids and Solids 0.35m (1.15ft). International explosion protection certificates.

Benefits

  • Reliable non-contact measurement
  • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
  • Envelope curves on the on-site display for simple diagnosis
  • Hermetically sealed and potted sensor
  • Chemically resistant sensor out of PVDF
  • Calibration without filling or discharging
  • Integrated temperature sensor for automatic correction of the temperature dependent sound velocity

Measuring principle

Ultrasonic

Characteristic / Application

Compact ultrasonic transmitter

Supply / Communication

2-wire HART

Accuracy

+/- 2 mm or +/- 0,2 % of set measuring range

Ambient temperature

-40 °C 80 °C

(-40 °F 176 °F)

Process temperature

-40 °C 80 °C

(-40 °F 176 °F)

Process pressure / max. overpressure limit

0.7 bar … 3 bar abs

(10 psi 44 psi)

Main wetted parts

PVDF

Process connection

G / NPT 2″

Blocking distance

0.35 m (1.15 ft)

Max. measurement distance

Liquids: 8 m (26 ft),

Solids: 3.5 m (11 ft)

Communication

4…20 mA HART

Certificates / Approvals

ATEX, FM, CSA, IEC, INMETRO, NEPSI

Application limits

For higher resistance:

FMU42/FDU9x

Foam / high turbulence possible:

FMU42/FDU91

Fast filling and discharging rate:

FMU90 + FDU9x

Level limit detection:

FMU90 + FDU9x

Features

  • Non-contact ultrasonic level/flow measurement using time-of-flight-principle.
  • Compact 2-wire or 4-wire version for liquids, pastes, coarse bulk materials and open-channel flow measurement.
  • Built-in temperature sensor for automatic correction of sound velocity for changing temperatures.
  • Menu-guided local operation via a four-line plain text display, selectable in seven languages.
  • Display “envelope curve” of the echo on-site for diagnostics of the echo signal.
  • Linearisation function up to 32 points—so the measured value can be converted into user units (length, volume, flow).
  • Housing materials and sensor wetted parts: PVDF sensor for chemical resistance; hermetically sealed/potted sensor.
  • Suitable for hazardous areas (explosion protection) in appropriate versions.