iTEMP TMT71 temperature transmitter

Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals. The standardized 4 to 20 mA output signal is used for process measurement. Swift and easy commissioning, operation and maintenance via PC software or with integrated Bluetooth® technology and Endress+Hauser SmartBlue App.

4-20 mA temperature transmitter as head, field or DIN rail device with one universal sensor input suitable for use in hazardous areas. Bluetooth®-enabled or PC programmable temperature transmitter for the conversion of various input signals into a scalable, analog 4 to 20 mA output signal. Improved process efficiency and increased plant uptime. Universal input for resistance thermometers (RTD), thermocouples (TC), resistance transmitters () and voltage transmitters (mV). Installation in terminal head form B as per DIN EN 50446. Installation in cabinets with DIN rail housing. Optional installation in field housing for Ex d applications.

Benefits

  • Safe operation in hazardous areas thanks to international approvals
  • Reliable operation thanks to sensor and device monitoring
  • Integrated Bluetooth® interface for the wireless display of measured values and configuration via Endress+Hauser SmartBlue App, optional
  • User-friendly guided user interface concept also on-site via Bluetooth®
  • Available with plug-on display TID10
  • Diagnostics information according to NAMUR NE 107

Measuring principle

Head transmitter

Input

1 x RTD, TC, Ohm, mV

Output

1 x analog 4…20 mA

Auxiliary power supply

10…36 V DC (Head transmitter)

11…36 V DC (DIN rail device)

10/11…30 V DC (Ex ia)

Communication

pc-programmable

Bluetooth® wireless technology

Installation

Terminal head form B / DIN rail / field mount housing

Accuracy

(Pt100, -50…200 °C) <= 0,1 K

(Pt100, -58…392 °F) <= 0,18 °F

Galvanic isolation

yes

Certification

ATEX Ex ia, Ex ic, Ex tc, Ex nA, Ex db, Ex tb

ATEX IECEx Ex ia, Ex tb

IECEx Ex d, Ex tb

CSA C/US General Purpose

CSA C/US IS, Ex ec, XP, DIP

INMETRO Ex ia, Ex d, Ex tb

NEPSI Ex ia, Ex d, Ex tb

EAC Ex ia, Ex d

UKCA Ex ia, Ex tc, Ex nA, Ex db, Ex tb

Features

  • Universal Input Types: Supports RTDs (e.g., Pt100), thermocouples (TC), resistance (Ω) and voltage (mV) signals.
  • Output: 4-20 mA analog loop.
  • Supply Voltage: Approx. 10 to 36 V DC (depending on variant) for the analog output version.
  • Accuracy Example: For Pt100 in the range –50 °C to +200 °C the accuracy is 0.1 K.
  • Diagnostics and Monitoring: Device includes sensor monitoring (open/short circuits, wiring faults) and diagnostics in line with NAMUR NE 107.
  • Wireless/Bluetooth: Optional integrated Bluetooth interface for wireless display and configuration using the SmartBlue app.
  • Easy Wiring: Optional push-in spring terminals for tool-free wiring.
  • Installation Flexibility: Terminal head (DIN EN 50446 form B), DIN-rail, or field housing (including Ex d versions) possible.