Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times. The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
The flowmeter for highest medium temperatures with an ultra-compact transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
DN 15 to 600 (½ to 24″)
Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)
Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
PN 40, Class 300, 20K
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
DN 15 to 300 (½ to 12″): AlSi10Mg, coated
DN 350 to 600 (14 to 24″): Carbon steel with protective varnish
AlSi10Mg, coated
IP66/67, type 4X enclosure
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
None
HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
DC 20 to 30 V
ATEX, IECEx, cCSAus, INMETRO
Product safety
CE, C-Tick
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
LR approval, DNV approval, ABS approval, BV approval
PED, CRN
3.1 material
Drinking water approval: ACS, NSF 61, WRAS
Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24″). All common Ex approvals. Liner made of PTFE or PFA.
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Local display available.